Horizon Technology Products

SPE consumables
Extraction Systems
Extraction Systems Controllers
Solid Phase Extraction Disks

Solvent Evaporation Systems
Solvent Recovery Systems

Concentrator System
Separation Membrane

.................................................................................................................,.....................................NEW Consumables Brochure

Extraction Systems

NEW SmartPrep® Extractor

SmartPrep is the first ever automated, small footprint, extraction system designed specifically for scalable cartridge based SPE of a wide range of contaminants in clean aqueous matrices. SmartPrep combines intelligence, versatility and ease of use making automated SPE simple and affordable for method developers and sample prep laboratories. The system enables the ability to apply unique methods to each sample or process (96) samples in batch mode. learn more







SPE-DEX® 4790 Extractor System

 


The SPE-DEX 4790® Automated Extraction System is a fully automated sample preparation system designed to rapidly process samples for trace level analysis of organic chemical contaminants from aqueous samples using EPA Methods for Solid Phase Extraction (SPE). learn more



SPE-DEX® 3000XL Extractor System

The SPE-DEX® 3000XL Automated Extractor System automates EPA Method 1664A and provides an alternative to expensive, labor intensive LLE methods for extracting oil and grease from aqueous samples. Using a combination of advanced liquid handling and Pacific™ O&G Disks, the SPE-DEX® 3000XL Extraction System delivers the accuracy and consistency of data laboratories need to comply with Method 1664A QC specifications. learn more

SPE-DEX® 1000XL Extractor System

A fully automated, single-station extraction system, the SPE-DEX® 1000XL Automated Extractor System provides maximum speed, accuracy, and simplicity for extracting a wide range of "clean" and "dirty" aqueous samples for oil & grease and non-polar material (NPM) by EPA Method 1664A. The SPE-DEX® 1000XL is ideal for facilities that process only a few samples each week. learn more

SPE-DEX® 4790 Extraction Systems Controller

Envision™ Platform Controller

The Envision™ Platform is the next generation controller for the SPE-DEX® 4790 Extractor system. Built on proven technology, it is the first web-based controller for SPE. The Envision™ Controller offers an easy-to-use, compact and user-friendly interface for controlling and interacting with up to eight extractors. You can develop, save, and transfer methods. learn more

SPE-DEX® 3000XL Oil & Grease Extraction Systems Controller

SPE-DEX® 3000XL Controller

The SPE-DEX® 3000XL extraction system controller is pre-programmed with EPA Method 1664A methods, ensuring you are in compliance with EPA Method 1664A modifications. The controller also has method modification capabilities for method development.



Solid Phase Extraction (SPE) Disks

Pacific™ & Pacific™ Premium O&G Disks
Using a combination of advanced liquid handling and Pacific™ O&G Disks, and the SPE-DEX® 3000XL Extraction System, you will receive the accuracy and consistency of data you need to comply with EPA Method 1664A QC specifications.
learn more

 


Atlantic™ SPE Disk

The Horizon Technology Atlantic™ SPE Disk is proven to be effective in extracting analytes from water samples, both drinking water and waster water. Using divinyl benzene (DVB) adsorbent, they are designed and certified for automation with the SPE-DEX® 4790 Automated Extractor.
learn more

Empore™ Extraction Disk
Empore extraction disks provide a sample prep solution for large volume samples. The disk format provides a large surface area for sorbent/sample contact. Faster
flow rates and higher throughput are realized compared to liquid-liquid extraction or traditional packed column technology. Click here to view application notes developed using 3M Empore Extraction Disks.


Solvent Evaporation Systems

Reclaimer™ SRS

The Reclaimer™ Solvent Recovery System is designed to condense and collect solvent vapors which are generated by Horizon Technology's DryVap® Concentrator System. Using a vacuum pump, the solvent vapors are pulled through a cold condenser coil, where the solvent vapors are chilled and converted back into a liquid form. learn more



Speed-Vap™ III

The Speed-Vap™ III Solvent Evaporation System provides safe and fast evaporation of n-hexane solvent for oil and grease extractions. A vortex airflow combined with precise temperature control enables the Speed-Vap™ III Evaporation System to quickly and safely evaporate n-hexane solvent from oil and grease extractions. learn more


Solvent Recovery Systems

Solvent Trap™

Solvent Trap The Solvent Trap™ Recovery System captures up to 70% of the n-hexane solvent vapor from EPA Method 1664A Oil & Grease extractions, minimizing the release of n-hexane into the atmosphere. learn more



Concentrator System

DryVap® Concentrator System

For environmental applications the DryVap® Concentrator System automates the drying, evaporation and concentration of organic extracts prior to GC and GC/MS analysis. Designed to emulate the traditional Kuderna Danish (KD) method, the DryVap® Concentrator System combines what were once manual steps into one automated process. Using a unique combination of vacuum, heat and sparge gas, the DryVap® Concentrator System rapidly evaporates and gently concentrates extractions down to a precise desired volume. learn more



Separation Membrane

DryDisk® Separation Membrane

DryDisk™ Separation Membranes offer a much more efficient means of drying solvents in organic extractions than sodium sulfate. Because it is a physical separation rather than a chemical process to remove residual water from organic solvent extractions, DryDisk™ membranes eliminate the problems inherent with chemical drying such as; retention of water-soluble compounds, over-saturation, caking, oven drying, messy waste removal, inability to handle emulsions. learn more

DryDisk® Separation Membrane 50 mL Disposable Barrel

The DryDisk® Separation Membrane 50 mL Barrel is a disposable sample preparation device that provides a fast and simple approach for removing residual water from non-polar solvents. The DryDisk® membrane replaces the conventional sodium sulphate drying technique. The barrel is made from high purity HDPE (high density polyethylene) and has a GORE-TEX® PTFE membrane embedded inside. learn more

SDS-101 Solvent Drying System

The SDS-101 Solvent Drying System simplifies and speeds up the solvent drying step in sample preparation. The system consists of the DryDiskTM Separation Membrane, PTFE Membrane Holder Assembly, precision controlled Vacuum Regulator, and Docking Bracket Assembly.

The SDS-101 is adaptable to common 1/2 in. diameter laboratory frames and can be mounted easily under the separatory funnel to collect the solvent extract. Quick disconnect fittings and detachable disk holders permits the collected residual water to be poured back into the separatory funnel for re-extraction and optimal recovery of analytes.
learn more


 