SmartPrep
is the first ever automated, small footprint, extraction
system designed specifically for scalable cartridge
based SPE of a wide range of contaminants in clean aqueous
matrices. SmartPrep combines intelligence, versatility
and ease of use making automated SPE simple and affordable
for method developers and sample prep laboratories.
The system enables the ability to apply unique methods
to each sample or process (96) samples in batch mode.
learn
more
|
SPE-DEX®
4790 Extractor System
|
The SPE-DEX 4790® Automated Extraction System is
a fully automated sample preparation system
designed to rapidly process samples for trace level
analysis of organic chemical contaminants from aqueous
samples using EPA Methods for Solid Phase Extraction
(SPE).
learn
more
|
SPE-DEX®
3000XL Extractor System
|
The SPE-DEX® 3000XL Automated Extractor System automates
EPA Method 1664A and provides an alternative to expensive,
labor intensive LLE methods for extracting oil and grease
from aqueous samples. Using a combination of advanced
liquid handling and Pacific O&G Disks, the SPE-DEX®
3000XL Extraction System delivers the accuracy and consistency
of data laboratories need to comply with Method 1664A
QC specifications. learn
more
|
SPE-DEX®
1000XL Extractor System
|
A
fully automated, single-station extraction system, the
SPE-DEX® 1000XL Automated Extractor System provides
maximum speed, accuracy, and simplicity for extracting
a wide range of "clean" and "dirty" aqueous samples for
oil & grease and non-polar material (NPM) by EPA Method
1664A. The SPE-DEX® 1000XL is ideal for facilities
that process only a few samples each week. learn
more
SPE-DEX®
4790 Extraction Systems Controller
|
Envision™
Platform Controller
|
The
Envision Platform is the next generation controller
for the SPE-DEX® 4790 Extractor system. Built on proven
technology, it is the first web-based controller for SPE.
The Envision Controller offers an easy-to-use, compact
and user-friendly interface for controlling and interacting
with up to eight extractors. You can develop, save, and
transfer methods. learn
more
SPE-DEX®
3000XL Oil & Grease Extraction Systems Controller
|
SPE-DEX®
3000XL Controller
|
The
SPE-DEX® 3000XL extraction system controller is pre-programmed
with EPA Method 1664A methods, ensuring you are in compliance
with EPA Method 1664A modifications. The controller also
has method modification capabilities for method development.
Solid
Phase Extraction (SPE) Disks
Pacific
& Pacific
Premium O&G
Disks
Using a combination of advanced liquid handling and
Pacific O&G Disks, and the SPE-DEX® 3000XL
Extraction System, you will receive the accuracy and
consistency of data you need to comply with EPA Method
1664A QC specifications.learn
more
Atlantic SPE Disk
The Horizon Technology Atlantic SPE Disk is proven
to be effective in extracting analytes from water samples,
both drinking water and waster water. Using divinyl
benzene (DVB) adsorbent, they are designed and certified
for automation with the SPE-DEX® 4790 Automated
Extractor. learn
more
Empore
Extraction Disk
Empore extraction disks provide a sample prep solution
for large volume samples. The disk format provides a large
surface area for sorbent/sample contact. Faster
flow rates and higher throughput are realized compared
to liquid-liquid extraction or traditional packed column
technology. Click
here to view application notes developed using 3M
Empore Extraction Disks.
Solvent
Evaporation Systems
The
Reclaimer™
Solvent Recovery System is designed to condense and
collect solvent vapors which are generated by Horizon
Technology's DryVap® Concentrator System. Using
a vacuum pump, the solvent vapors are pulled through
a cold condenser coil, where the solvent vapors are
chilled and converted back into a liquid form. learn
more
The
Speed-Vap™ III Solvent Evaporation System provides safe
and fast evaporation of n-hexane solvent for oil and grease
extractions. A vortex airflow combined with precise temperature
control enables the Speed-Vap™ III Evaporation System
to quickly and safely evaporate n-hexane solvent from
oil and grease extractions. learn
more
Solvent Recovery Systems
The
Solvent Trap™
Recovery System captures up to 70% of the n-hexane solvent
vapor from EPA Method 1664A Oil & Grease extractions,
minimizing the release of n-hexane into the atmosphere.
learn
more
Concentrator
System
|
DryVap®
Concentrator System
|
For
environmental applications the DryVap® Concentrator
System automates the drying, evaporation and concentration
of organic extracts prior to GC and GC/MS analysis.
Designed to emulate the traditional Kuderna Danish (KD)
method, the DryVap® Concentrator System combines
what were once manual steps into one automated process.
Using a unique combination of vacuum, heat and sparge
gas, the DryVap® Concentrator System rapidly evaporates
and gently concentrates extractions down to a precise
desired volume. learn
more
Separation
Membrane
|
DryDisk®
Separation Membrane
|
DryDisk™
Separation Membranes offer a much more efficient means
of drying solvents in organic extractions than sodium
sulfate. Because it is a physical separation rather than
a chemical process to remove residual water from organic
solvent extractions, DryDisk™
membranes eliminate the problems inherent with chemical
drying such as; retention of water-soluble compounds,
over-saturation, caking, oven drying, messy waste removal,
inability to handle emulsions. learn
more
|
DryDisk®
Separation Membrane 50
mL Disposable
Barrel
|
The
DryDisk®
Separation Membrane 50 mL Barrel is a disposable sample
preparation device that provides a fast and simple approach
for removing residual water from non-polar solvents. The
DryDisk®
membrane replaces
the conventional sodium sulphate drying technique. The
barrel is made from high purity HDPE (high density polyethylene)
and has a GORE-TEX® PTFE membrane embedded inside.
learn
more
|
SDS-101
Solvent Drying System
|
The
SDS-101 Solvent Drying System simplifies and speeds up
the solvent drying step in sample preparation. The system
consists of the DryDiskTM Separation Membrane, PTFE Membrane
Holder Assembly, precision controlled Vacuum Regulator,
and Docking Bracket Assembly.
The SDS-101 is adaptable to common 1/2 in. diameter laboratory
frames and can be mounted easily under the separatory
funnel to collect the solvent extract. Quick disconnect
fittings and detachable disk holders permits the collected
residual water to be poured back into the separatory funnel
for re-extraction and optimal recovery of analytes. learn
more
|